Peripherals

 

ProTime PT/INR:

The ProTimeMicrocoagulation System for prothrombin time testing is designed to safely manage Coumadin® therapy. The ProTime System consists of the ProTime instrument, the 3-channel reagent cuvette with built-in quality control, and the Tenderlett® Plus LV sample collection system. The test procedure is simple, and performance is comparable to laboratories.

 

 

For use with The American TeleCare® Video Patient Station or Patient Monitoring Station:

  • Integrated on-board quality controls
  • Sensitive thromboplastin (ISI=1.0)
  • Results reported in INR and PT seconds (% Quick can be selected
  • CLIA waived
  • Approved for patient self-testing. Allows for more frequent testing for better control and fewer complications.

ProTime enables your patients to do prothrombin time (PT) testing at home. This test is done to check the status of their oral anti-coagulation therapy. Results are reported in both INR and PT seconds. The reagents (substances that are used to run the test) are inside the specially designed cuvette. Just a drop and a half of blood and a fresh cuvette are needed to run the test. No measuring or mixing blood or reagents - ProTime does it all for you in the convenience of your patient's home.

Many insurance companies will pay for your ProTime System. They too want to keep patients out of the hospital. A few examples of patients who are at high risk for bleeding or clotting complications include:

Patients who:

 

  • Have taken anti-coagulation therapy for a long period of time
  • Are managed with high intensity therapy (patients with a mechanical heart valve)
  • Experienced bleeding or clotting complications in the past
  • Fluctuate widely in their response to anticoagulation therapy
LifeSource™ Digital Scale:

Patients can take weight measurements at any time during the day or night. Readings are time and date stamped and stored for transfer to the Video Patient Station or Monitoring Station during a telehealth encounter. Use with either the Video Patient Station or Monitoring Station.

Specifications for Standard Scale:

  • Size:
    12.25" x 12.25" x 2.05"
  • Weight:
    Approximately 5 lbs.
  • Power:
    Uses four AA batteries
  • Load:
    0.1 to 350 lbs.
  • Memory (measurement storage capacity):
    50+ readings
  • Display:
    Liquid crystal, 1" character height

*Specifications for 500 pound scale are also available

BCI® Pulse Oximeter:

During a telecare connection the nurse can take oxygen saturation and pulse readings and transmit them on command as a live stream feed via the Video Patient Station or Monitoring Station to the Provider Station. Readings also can be taken by the patient, are time and date stamped, and stored in the meter for transfer at a later time. Use with either the Video Patient Station or Monitoring Station.

Specifications:

  • Weight:
    1.2 lbs. with batteries
  • Display:
    LED
  • Power:
    Uses three C batteries
  • Display/Keys:
    SpO2- .43" high, LED numeric; pulse- .375" LED numeric; pulse strengthlogarithmically scaled 8-segment LED bar graph; I & O keys; display update- 1Hz (SpO2); 60Hz (pulse strength)
  • Pulse Rate Range:
    30 to 254 bpm (± 2% at 30 to 254 bpm), 8 second average
  • Environmental Requirements:
    0 to 55 C (32 to 131 F) operating temperature; -34 to 70 C (-29 to 158 F) storage temperature; 10 to 95% relative-humidity (non-condensing) storage; 15 to 95% relative humidity (non-condensing) operating
CareTone® Telephonic Stethoscope:

Please see the individual product sheet for detailed information regarding the CareTone Telephonic Stethoscope

OneTouch® Glucose Meter:

Portable and convenient, the Glucose Meter can be used by a patient at any time, to take glucose readings. Each reading is time and date stamped and stored in the meter for transfer via the Video Patient Station or Monitoring Station.
 

Specifications:

  • Size:
    3.2" x 2.3" x 0.8"
  • Weight:
    1.6 ounces
  • Power:
    Uses one 3 V lithium cell battery
  • Result Range:
    20 to 600 mg/dL (0 to 27.8 mmol/L); higher results displayed as "HI"
  • Hematocrit Range:
    30 to 55%
  • Calibration:
    Plasma equivalent
  • Memory:
    150 blood glucose and control solution tests